List of AskiaWeb error codes:
| Error Code | Caption | Description | Resolution |
| 101 | ERR_BDDCANNOTOPENMAINDATABASE | Cannot open WebProd Database | |
| 102 | ERR_BDDCANNOTOPENQRETABLE | Cannot open WP_Survey table | |
| 103 | ERR_BDDQRENOTFOUND | Cannot find questionnaire file | |
| 104 | ERR_BDDCANNOTREADQSTRE | Problem reading WP_Survey table | |
| 105 | ERR_CANNOTREADQES | Cannot open questionnaire file | |
| 109 | ERR_BDDUNKNOWN | Error unknown | |
| 111 | ERR_BDDCANNOTOPENCONSTTABLE | Cannot read WP_Const table | |
| 112 | ERR_CANNOTSAVESETTINGSQES | Cannot save settings in questionnaire file | |
| 113 | ERR_CANNOTSAVESETTINGSMAIN | Cannot save settings in WebProd database | |
| 114 | ERR_CANNOTGETID | Cannot get new number for interview | |
| 115 | ERR_CANNOTCREATEMASK | Cannot create a screen for entry (not questions?) | |
| 116 | ERR_CANNOTSAVEINTERVIEW | Cannot save intvw file (workdirectory doesn't exist or has no write rights) | |
| 117 | ERR_CANNOTREADINTERVIEW | Cannot read intvw file (file is deleted or directory has changed...) | |
| 118 | ERR_CANNOTFINDSCREEN | Cannot find entry screen | |
| 119 | ERR_CANNOTUNLOAD | Questionnaire isn't loaded | |
| 120 | ERR_CANNOTGETPANELDATA | ||
| 121 | ERR_INVALIDPANELID | ||
| 122 | ERR_CANNOTCREATEDESTINATION | ||
| 123 | ERR_CANNOTLOCKMASK | ||
| 666 | ERR_CANNOTCREATEDESTINATION | Cannot open WebProd Database | |
| 667 | ERR_CANNOTCREATEDESTINATION | Cannot create zip file, check that AskiaZipper.dll is correctly registered | |
| 668 | ERR_CANNOTCREATEDESTINATION | Your database WebProd is not updated | |
| 669 | ERR_CANNOTCREATEDESTINATION | There is an incompatibility between WebProd pages and AskiaExt | |
| 1001 | IDS_ERR_ASKIAEXT1__NO_PARAMETER | No parameter | No parameters were specified in the AskiaExt URL, for example:http://survey.askia.com/webprod/askiaext.dll? |
| 1002 | IDS_ERR_ASKIAEXT2__NO_ACTION | No Action parameter | The parameter Action or MFCIsapiCommand was missing in the AskiaExt URL. |
| 1003 | IDS_ERR_ASKIAEXT3__NO_QUESTIONNAIRE | No questionnaire parameter | The parameter used to identify the survey is missing, either Survey,SurveyName or T1. |
| 1004 | IDS_ERR_ASKIAEXT4__TOO_MANY_PARAMETERS | Too many parameters | Not used - deprecated |
| 1005 | IDS_ERR_ASKIAEXT5__TOO_LITTLE_PARAMETERS | Not enough parameters | Parameter(s) required to process an Action are missing. The necessary parameters depend on the Action. |
| 1006 | IDS_ERR_ASKIAEXT6__PARAMETER_MISSING | Missing parameter | One or more parameters, required to process the Action requested, are missing. The necessary parameters depend on the requestedAction. |
| 1007 | IDS_ERR_ASKIAEXT7__EXPECTED_PARAMETER | Expected parameter | The system failed to decoded a parameter encoded via Key16. |
| 1008 | IDS_ERR_ASKIAEXT8__INCORRECT_PARAMETER | Incorrect parameter | A parameter contained an invalid value, such as a Numeric parameter which wasn't numeric, or a call made to an inexistent Action. |
| 10035 | No response from CCA | Check your network settings. Try to ping your CCA, etc... |
Here, the error messages as they are displayed on respondent side:
Error 100 is unknown error:
IDS_UNKNOWN_ERROR: "Unknown error"
Error 101-123 will use this error:
IDS_QUESTIONNAIRENONDISPONIBLE_N: "Questionnaire '%s' not available (cause %d)"
Error 124 will use this error:
IDS_ERR_ASKIAEXT9__READ_UPDATE_SOURCE: "Could not read update source: %s"
Errors 1001-1008 use these errors:
IDS_ERR_ASKIAEXT1__NO_PARAMETER: "Askia Web : Error 1001 (No parameter)"
IDS_ERR_ASKIAEXT2__NO_ACTION: "Askia Web : Error 1002 (No parameter Action)"
IDS_ERR_ASKIAEXT3__NO_QUESTIONNAIRE: "Askia Web : Error 1003 (No parameter questionnaire)"
IDS_ERR_ASKIAEXT4__TOO_MANY_PARAMETERS: "Askia Web : Error 1004 (Too many parameters)"
IDS_ERR_ASKIAEXT5__TOO_LITTLE_PARAMETERS: "Askia Web : Error 1005 (Not enough parameters)"
IDS_ERR_ASKIAEXT6__PARAMETER_MISSING: "Askia Web : Error 1006 (Parameter missing)"
IDS_ERR_ASKIAEXT7__EXPECTED_PARAMETER: "Askia Web : Error 1007 (Expected parameter)"
IDS_ERR_ASKIAEXT8__INCORRECT_PARAMETER:"Askia Web : Error 1008 (Incorrect parameter)"